How much clean air does your space need?

Explore how floor area, ceiling height and operating level affect clean-air delivery. Then see why room layout and airflow deserve a closer look.

Clean-air planning calculator

Same square footage. Different clean-air needs.

Floor area600 square feet

Length × width. Ceiling height changes volume, not floor area.

How should the cleaner operate?

Calculate the CADR needed to maintain your target as room dimensions change.

Adjust the level. Maintain the rate.

Use + / − or enter your dimensions.

5 is an illustrative starting point. Your eACH requirements may differ.

Your roomConceptual illustration

20 × 30 × 8 ft

What this result means

Your target requires 400 cubic feet of clean air per minute. Over an hour, that equals 5 times this room’s air volume.

Air mixes and recirculates, so this doesn’t mean every part of the room is cleaned 5 times.

Required total CADR400 cfm

To maintain 5 cleaner eACH

Same CADR as the starting example

Floor area600 ft²Length × width
Room volume4,800 ft³Floor area × height
Target cleaner eACH5.00 / hourHeld constant as dimensions change
Starting example: 20 × 30 × 8 ft400 cfm at the same target4,800 ft³ reference · same volume

What changes?

Adjust the operating level to match the room.

For example, at a target of 5 eACH, raising a 600-square-foot space’s ceiling from 8 to 12 feet increases required CADR from 400 to 600 cfm. A different operating level may meet that need. For Tatama, compare the result with measured CADR at each level.

CADR supports air cleaner comparisons under standardized test conditions. Neither CADR nor calculated eACH establishes air distribution or measured effectiveness in an occupied room.

Beyond the calculation · Spatial model

Air cleaning depends on where the air reaches

HVAC supply and return locations shape circulation. This illustration shows one possible path; actual airflow depends on the room and system.

  • Illustrative HVAC path
  • Illustrative particle source

Conceptual illustration, not to scale. Paths do not represent measured airflow or particle concentration.

Swipe to explore the room illustration →

HVAC SUPPLYHVAC RETURN PARTICLE SOURCE PORTABLECLEANER TATAMA, IN-CEILING INSTALLATIONCEILING DIFFUSERCEILING INTAKE

Further reading: "The Crucial Role of Ventilation Effectiveness in Air Cleaning", International Filtration News.

Calculations, assumptions & sources

The calculator uses room volume and the cleaner's published CADR at the operating level you enter. These figures are planning estimates, not a measure of airflow or performance throughout an occupied room.

Room volume
Length × width × ceiling height, in ft³.
Cleaner eACH
CADR (cfm) × 60 ÷ room volume (ft³).
Required CADR
Room volume × target cleaner eACH ÷ 60.

Assumes a rectangular room and uniform ceiling height. HVAC and outdoor-air contributions are excluded. The 5 eACH starting target is illustrative. Placement, partitions and mixing can affect actual conditions. Air cleaning does not replace required ventilation.

Further reading: EPA air cleaner guide · Portable Air Cleaner Sizing Tool - Healthy Buildings at Harvard School of Public Health · AHAM Verifide air cleaner directory and sizing guidance · CDC/NIOSH ventilation FAQ.

From calculation to observation

What would you like to understand?

Select a question to explore a practical next step.

Compare monitored conditions before and after a documented change, while considering activities and other conditions. Pasoh can help reveal patterns worth investigating.

Explore Pasoh monitoring, a focused pilot or assessment, or Tatama equipment.

Included with your inquiry

Edit calculator inputs